Instructions:
To set the start temperature:
Press the UP button once to display the start temperature. Hold the UP button for approximately 3 seconds. The start temperature digits will flash. Use the UP and DOWN buttons to set the desired temperature value.
To set the stop temperature:
Press the DOWN button once to display the stop temperature. Hold the button for approximately 3 seconds. The stop temperature number will flash, and the desired temperature value can be set using the UP and DOWN buttons.
To restore factory settings:
While switching on the device, press and hold the up and down buttons simultaneously. The digital display will show 888 and then automatically jump to the detection temperature, restoring the factory settings.
Specification:
Temperature measuring range: -50 ~ 125 C
Temperature measurement accuracy: 0.2 C
Temperature control precision: 0.1 C
Input measurement: 1M waterproof probe
Input power: AC 110-220V
Output: max 10A
Output power: 1500W
What's in the box
4 x XH-W3001 Digital Temperature Controller with Sensor and LCD Display