SALE
DFR ANALOG HI EC Conductivity Sensor K10 for High Conductivity Liquids

DFR ANALOG HI EC Conductivity Sensor K10 for High Conductivity Liquids

Features - Laboratory-grade analog electrical conductivity sensor - Designed for high-conductivity liquids including sea…
No reviews yet
R 184.00R 209.89
🚚 Ships in 6-8 work days

Features - Laboratory-grade analog electrical conductivity sensor - Designed for high-conductivity liquids including seawater and brine - Measures conductivity from 10 to 100mS/cm - K=10 laboratory-gr...

🛡️
Warranty
6-Month Limited Warranty.
↩️
Return Policy
Hassle-Free Exchanges & Returns for 7 Days.

Product Information

SKU102375686
Stock StatusIn Stock
Safe Checkout

Buy Now, Pay Later

Split your purchase into easy payments

Interest Rate0% Interest
Payment Period3 months
Sale Product - Fixed Term
  • 30% deposit then pay monthly - that's only R 55.20 upfront!
  • No interest - you only pay the product price
  • Quick approval - decision within 1-2 business days
  • Secure - ID verification required for your protection

Features
- Laboratory-grade analog electrical conductivity sensor
- Designed for high-conductivity liquids including seawater and brine
- Measures conductivity from 10 to 100mS/cm
- K=10 laboratory-grade conductivity probe
- AC excitation minimizes electrode polarization
- Supports simple single-point calibration
- Automatic recognition of standard buffer solutions
- Analog output compatible with ADC-equipped microcontrollers
- Gravity plug-and-play interface for rapid installation
- Compatible with Arduino, Raspberry Pi, ESP32 and other platforms
- BNC-connected removable probe
- Includes calibration solutions and mounting accessories
Applications
- Marine aquaculture
- Seawater monitoring
- Saltwater aquariums
- Wastewater conductivity measurement
- Industrial process monitoring
- Water quality monitoring systems
- Environmental monitoring
- DIY multi-parameter water quality analyzers
Specifications
- Signal Conversion Board
- Supply Voltage: 3.0V-5.0V DC
- Output Voltage: 0-3.2V Analog
- Probe Connector: BNC
- Signal Connector: PH2.0 3-Pin Gravity
- Measurement Accuracy: 5% Full Scale
- Board Dimensions: 42 × 32mm
- Electrical Conductivity Probe
- Probe Type: Laboratory Grade
- Cell Constant: K=10 2
- Measurement Range: 10-100mS/cm
- Operating Temperature: 0 C to +40 C
- Probe Life: >0.5 years (application dependent)
- Cable Length: 100 2cm
Package Contents
- Laboratory-grade K=10 EC Probe
- Analog Signal Conversion Board
- 12.88mS/cm Standard Buffer Solution ×4
- Gravity Analog Sensor Cable
- Waterproof Gaskets ×2
- BNC Connector Screw Cap
- M3 Nylon Mounting Pillars ×4
- M3 Mounting Screws ×8
Operational Notes
- Do not leave the probe permanently immersed in liquid, as this will reduce its service life.
- Clean the probe only with distilled water. Avoid touching the platinum black sensing surface, as damage to this coating will affect measurement accuracy.
- For the highest accuracy, use an external waterproof temperature sensor to provide automatic temperature compensation.

What's in the box
1 x DFR ANALOG HI EC Conductivity Sensor K10 for High Conductivity Liquids

Features
- Laboratory-grade analog electrical conductivity sensor
- Designed for high-conductivity liquids including seawater and brine
- Measures conductivity from 10 to 100mS/cm
- K=10 laboratory-grade conductivity probe
- AC excitation minimizes electrode polarization
- Supports simple single-point calibration
- Automatic recognition of standard buffer solutions
- Analog output compatible with ADC-equipped microcontrollers
- Gravity plug-and-play interface for rapid installation
- Compatible with Arduino, Raspberry Pi, ESP32 and other platforms
- BNC-connected removable probe
- Includes calibration solutions and mounting accessories
Applications
- Marine aquaculture
- Seawater monitoring
- Saltwater aquariums
- Wastewater conductivity measurement
- Industrial process monitoring
- Water quality monitoring systems
- Environmental monitoring
- DIY multi-parameter water quality analyzers
Specifications
- Signal Conversion Board
- Supply Voltage: 3.0V-5.0V DC
- Output Voltage: 0-3.2V Analog
- Probe Connector: BNC
- Signal Connector: PH2.0 3-Pin Gravity
- Measurement Accuracy: 5% Full Scale
- Board Dimensions: 42 × 32mm
- Electrical Conductivity Probe
- Probe Type: Laboratory Grade
- Cell Constant: K=10 2
- Measurement Range: 10-100mS/cm
- Operating Temperature: 0 C to +40 C
- Probe Life: >0.5 years (application dependent)
- Cable Length: 100 2cm
Package Contents
- Laboratory-grade K=10 EC Probe
- Analog Signal Conversion Board
- 12.88mS/cm Standard Buffer Solution ×4
- Gravity Analog Sensor Cable
- Waterproof Gaskets ×2
- BNC Connector Screw Cap
- M3 Nylon Mounting Pillars ×4
- M3 Mounting Screws ×8
Operational Notes
- Do not leave the probe permanently immersed in liquid, as this will reduce its service life.
- Clean the probe only with distilled water. Avoid touching the platinum black sensing surface, as damage to this coating will affect measurement accuracy.
- For the highest accuracy, use an external waterproof temperature sensor to provide automatic temperature compensation.

What's in the box
1 x DFR ANALOG HI EC Conductivity Sensor K10 for High Conductivity Liquids

More in Sensors