SALE
DC AC Current Clamp and Multimeter 6000 Counts True RMS

DC AC Current Clamp and Multimeter 6000 Counts True RMS

6000 Counts True RMS Digital Multimeter Clamp Meter Feature 1-1. Display: liquid crystal display (LCD); 1-2. Maximum dis…
4.713 Reviews
R 39.00R 50.87
🚚 Ships in 16-18 work days

6000 Counts True RMS Digital Multimeter Clamp Meter Feature 1-1. Display: liquid crystal display (LCD); 1-2. Maximum display: 5999 (3 5/6) bit automatic polarity display; 1-3. Measurement method: doub...

🛡️
Warranty
6-Month Limited Warranty.
↩️
Return Policy
Hassle-Free Exchanges & Returns for 7 Days.

Product Information

SKU73714953
Stock StatusIn Stock
Safe Checkout

6000 Counts True RMS Digital Multimeter Clamp Meter
Feature
1-1. Display: liquid crystal display (LCD);
1-2. Maximum display: 5999 (3 5/6) bit automatic polarity display;
1-3. Measurement method: double integral A/D conversion;
1-4. Sampling rate: 3 times per second;
1-5. Over range display: The highest position shows "OL";
1-6. Low voltage display: “Low voltage symbol "symbol appears;
1-7. Working environment:(0?40) °, relative humidity?80%;
1-8. Power: AAA 1.5V battery (not included);

NOTE:
This series of instruments are designed in accordance with IEC1010 (Safety Standards promulgated by the International Electrotechnical Commission), please read the safety precautions before use.
1. When measuring voltage, please do not input the limit voltage exceeding the effective value of DC 1000V or AC 750V;
2. The voltage below 2.36V is a safe voltage. When measuring higher than 36V DC and 25V AC voltage, check whether the test leads are in reliable contact, are connected correctly, and are well insulated to avoid electric shock;
3. When changing functions and ranges, the test leads should leave the test point.

Function
Range Accuracy Resolution
DC Voltage 6V/60V/600V +-(0.8%+10) 0.001V/0.01V/0.1V
DC Voltage 1000V +-(0.5%+3) 1V
AC Voltage 6V/60V/600V +-(0.8%+3) 0.001V/0.01V/0.1V
AC Voltage 750V +-(1.2%+10) 1V
DC Current 60A/600A +-(2.5%+30) 0.01A/0.1A
AC Current 60A/600A +-(2.5%+30) 0.01A/0.1A
Resistance 600? +-(0.8%+5) 0.1
6k?/60k?/600k?/6M? +-(0.8%+3) 1/10/100/1k
40M? +-(2.5%+3) 10k
Capacitance 60nF/600nF/6uF/60uF/600uF +-(3.5%+20) 10pF/100pF/1nF/10nF/100nF
6mF/30mF +-(5%+3) 1uF/10uF
Frequency 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz +-(0.1%+3) 0.01Hz/0.1Hz/1Hz/10Hz/100Hz/1kHz/10kHz
Temperature (-20~1000?) As the Instructions 1?
(0~1832?) As the Instructions 1?

Function:
DC Voltage: DCA
AC Voltage ACV
DC Current: DCA
AC Current ACA
Resistor :
Frequency
Square Wave Output:
NCV:
On-off Test
Full Unit Symbol
Backlight Manual/Auto-Off
True RMS Measure
Temperature
Flashlight Lighting
Diode
Capacitor

What's in the box
1x ST209 Clamp meter
1x Test pen,
1x Temperature probe
1x Storage bag
1x Instruction manual
1x Screen Wipe
1x quick start guide
1x red 43cm clip on lanyard with 2cm keyring

6000 Counts True RMS Digital Multimeter Clamp Meter
Feature
1-1. Display: liquid crystal display (LCD);
1-2. Maximum display: 5999 (3 5/6) bit automatic polarity display;
1-3. Measurement method: double integral A/D conversion;
1-4. Sampling rate: 3 times per second;
1-5. Over range display: The highest position shows "OL";
1-6. Low voltage display: “Low voltage symbol "symbol appears;
1-7. Working environment:(0?40) °, relative humidity?80%;
1-8. Power: AAA 1.5V battery (not included);

NOTE:
This series of instruments are designed in accordance with IEC1010 (Safety Standards promulgated by the International Electrotechnical Commission), please read the safety precautions before use.
1. When measuring voltage, please do not input the limit voltage exceeding the effective value of DC 1000V or AC 750V;
2. The voltage below 2.36V is a safe voltage. When measuring higher than 36V DC and 25V AC voltage, check whether the test leads are in reliable contact, are connected correctly, and are well insulated to avoid electric shock;
3. When changing functions and ranges, the test leads should leave the test point.

Function
Range Accuracy Resolution
DC Voltage 6V/60V/600V +-(0.8%+10) 0.001V/0.01V/0.1V
DC Voltage 1000V +-(0.5%+3) 1V
AC Voltage 6V/60V/600V +-(0.8%+3) 0.001V/0.01V/0.1V
AC Voltage 750V +-(1.2%+10) 1V
DC Current 60A/600A +-(2.5%+30) 0.01A/0.1A
AC Current 60A/600A +-(2.5%+30) 0.01A/0.1A
Resistance 600? +-(0.8%+5) 0.1
6k?/60k?/600k?/6M? +-(0.8%+3) 1/10/100/1k
40M? +-(2.5%+3) 10k
Capacitance 60nF/600nF/6uF/60uF/600uF +-(3.5%+20) 10pF/100pF/1nF/10nF/100nF
6mF/30mF +-(5%+3) 1uF/10uF
Frequency 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz +-(0.1%+3) 0.01Hz/0.1Hz/1Hz/10Hz/100Hz/1kHz/10kHz
Temperature (-20~1000?) As the Instructions 1?
(0~1832?) As the Instructions 1?

Function:
DC Voltage: DCA
AC Voltage ACV
DC Current: DCA
AC Current ACA
Resistor :
Frequency
Square Wave Output:
NCV:
On-off Test
Full Unit Symbol
Backlight Manual/Auto-Off
True RMS Measure
Temperature
Flashlight Lighting
Diode
Capacitor

What's in the box
1x ST209 Clamp meter
1x Test pen,
1x Temperature probe
1x Storage bag
1x Instruction manual
1x Screen Wipe
1x quick start guide
1x red 43cm clip on lanyard with 2cm keyring

More in Scanners & Testers